Voltage Output Modules, Bandwith 400 Hz

Each SCM5B49 voltage output module provides a single channel of analog output. The track-and-hold circuit in the input stage can be operated in a hold mode where one DAC can supply many output modules, or a track mode where one DAC is dedicated to each module. In addition to the track-and-hold circuit, each module provides signal buffering, isolation, filtering, and conversion to a high-level voltage output.

Setting of the track or hold mode is controlled by the logic state of WR EN\, module pin 23. When pin 23 is low, the track mode is enabled. If pin 23 is high, the hold mode is enabled. The module is designed with a completely isolated computer side circuit which can be floated to ± 50 V from Power Common, pin 16. This complete isolation means that no connection is required between I/O Common and Power Common for proper operation of the track and hold circuit. For a low state, simply connect pin 23, the Write-Enable pin, to I/O Common, pin 19.

The SCMPB02 and SCMPB06 backpanels allow host computer control of the WR EN\ control line, which allows multiplexing of one host DAC to up to 64 SCM5B49 output modules.

Circuit diagram Dataforth SCM5B49

Block Diagram SCM5B49



PDF Downloads:


7 Modules for Type SCM5B49:

ModuleInputDescription
SCM5B49-01 0 to +5 V SCM5B49 Isolated Voltage Output Module with Voltage-Input
SCM5B49-02 -5 to +5 V SCM5B49 Isolated Voltage Output Module with Voltage-Input
SCM5B49-03 -5 to +5 V SCM5B49 Isolated Voltage Output Module with Voltage-Input
SCM5B49-04 0 to +10 V SCM5B49 Isolated Voltage Output Module with Voltage-Input
SCM5B49-05 -10 to +10 V SCM5B49 Isolated Voltage Output Module with Voltage-Input
SCM5B49-06 -10 to +10 V SCM5B49 Isolated Voltage Output Module with Voltage-Input
SCM5B49-07 -5 to +5 V SCM5B49 Isolated Voltage Output Module with Voltage-Input

Specifications

top
  • Input: V-Signal
  • Output: 0V…+5V / 0V…+10V / -5V…+5V / -10V…+10V
  • Bandwidth 400 Hz
  • Isolation 1500 Vrms
  • Input protection ± 36 V
  • Input Resistance 50 MOhm
  • Accuracy ± 0.03%
  • Linearity ±0.015%
  • ANSI/IEEE C37.90.1 Input protection
  • CMR 110dB
  • True 3-way isolation
  • 240 Vrms Output Protection
  • Power Supply +5 VDC
  • Operating Temperature Range -40°C … +85°C
  • Mix and Match Types on Backpanels possible
  • Dimensions 58 x 57 x 15 mm
  • Optional DIN Rail Mounting
  • CSA certified, CE and ATEX compliant
  • Wide range of accessories